Novel lossy compression method of noisy time series data with anomalies: Application to partial discharge monitoring in overhead power lines

L Klein, J Dvorský, D Seidl, L Prokop - Engineering Applications of Artificial …, 2024 - Elsevier
In overhead power transmission lines, particularly in regions like natural parks where
establishing a safe zone is difficult, the adoption of cross-linked polyethylene insulated …

Partial discharge localization based on received signal strength

H Mohamed, P Lazaridis, D Upton… - … on Automation and …, 2017 - ieeexplore.ieee.org
Partial Discharge (PD) occurs when insulation containing defects or voids is subject to high
voltages. If left untreated PD can degrade insulation until, eventually, catastrophic insulation …

Partial discharge detection and localization: Using software-defined radio

H Mohamed, P Lazaridis, P Mather… - IEEE Industrial …, 2019 - ieeexplore.ieee.org
Partial discharge (PD) occurs when insulation containing voids is subjected to high voltage
(HV). If left untreated, PD can degrade insulation until, eventually, catastrophic insulation …

A novel method for separating and locating multiple partial discharge sources in a substation

P Li, W Zhou, S Yang, Y Liu, Y Tian, Y Wang - Sensors, 2017 - mdpi.com
To separate and locate multi-partial discharge (PD) sources in a substation, the use of
spectrum differences of ultra-high frequency signals radiated from various sources as …

Validation of partial discharge emulator simulations using free-space radiometric measurements

A Jaber, P Lazaridis, B Saeed, Y Zhang… - … for Students on …, 2016 - ieeexplore.ieee.org
A useful technique to estimate the degradation of insulation in high voltage (HV) installations
is the measurement of partial discharge (PD). Free-space radiometric (FSR) detection of PD …

Radio-frequency localization of multiple partial discharges sources with two receivers

G Robles, JM Fresno, JM Martínez-Tarifa - Sensors, 2018 - mdpi.com
Spatial localization of emitting sources is especially interesting in different fields of
application. The focus of an earthquake, the determination of cracks in solid structures, or …

Partial discharge detection in smart grid using software defined radio

H Mohamed, PI Lazaridis, U Khan… - 2017 25th …, 2017 - ieeexplore.ieee.org
Smart grid is the term used to describe the next generation power grid in which the
management of electricity distribution is enhanced by advanced two-way communications …

Use of optimized centroid and weighted centroid algorithms to locate a partial discharge source by using received signal strength

UF Khan, GMW Janjua, A Ayub, MA Ilyas… - 2020 23rd …, 2020 - ieeexplore.ieee.org
Received signal strength (RSS) based localization of a source is a simple but effective
technique. In RSS based localization source location is estimated by converting obtained …

Partial discharge angle of arrival estimation using UHF wireless sensor array

L Ren, T Jia, A Sun, N Zheng, F Wu… - IOP Conference Series …, 2019 - iopscience.iop.org
The detection and localization of partial discharge (PD) in air-insulated substations by ultra-
high frequency (UHF) technology is widely studied. Existing UHF PD localization system …

WSN integrated to a virtual instrument for partial discharges detection and localization

RALV de Omena, JJ Silva… - 2018 IEEE International …, 2018 - ieeexplore.ieee.org
Failures in insulation of power systems equipment can causes irreparable damages and
interruption of power supplying. A potential cause for these failures is the occurrence of …