Comparison between ray-tracing and full-wave simulation for transcranial ultrasound focusing on a clinical system using the transfer matrix formalism

T Bancel, A Houdouin, P Annic… - IEEE transactions on …, 2021 - ieeexplore.ieee.org
Only one high-intensity focused ultrasound device has been clinically approved for
transcranial brain surgery at the time of writing. The device operates within 650 and 720 kHz …

Comparison of two viscoacoustic propagators for -compensated reverse time migration

P Guo, GA McMechan, H Guan - Geophysics, 2016 - library.seg.org
Without considering intrinsic attenuation, reverse time migration (RTM) of data from lossy
media produces smeared migration images because of the Q effects (amplitude loss and …

Medium access control and rate adaptation for ultrasonic intrabody sensor networks

GE Santagati, T Melodia, L Galluccio… - … /ACM Transactions on …, 2014 - ieeexplore.ieee.org
The use of wirelessly internetworked miniaturized biomedical devices is promising a
significant leap forward in medical treatment of many pervasive diseases. Recognizing the …

Estimation of tissue attenuation from ultrasonic B-mode images—Spectral-log-difference and method-of-moments algorithms compared

DM Brandner, X Cai, J Foiret, KW Ferrara, BG Zagar - Sensors, 2021 - mdpi.com
We report on results from the comparison of two algorithms designed to estimate the
attenuation coefficient from ultrasonic B-mode scans obtained from a numerical phantom …

Computationally efficient transcranial ultrasonic focusing: Taking advantage of the high correlation length of the human skull

G Maimbourg, J Guilbert, T Bancel… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
The phase correction necessary for transcranial ultrasound therapy requires numerical
simulation to noninvasively assess the phase shift induced by the skull bone. Ideally, the …

Simulation of x‐ray‐induced acoustic imaging for absolute dosimetry: Accuracy of image reconstruction methods

F Forghani, A Mahl, TJ Patton, BL Jones… - Medical …, 2020 - Wiley Online Library
Purpose Three‐dimensional in‐vivo dose verification is one of the standing challenges in
radiation therapy. X‐ray‐induced acoustic tomography has recently been proposed as an …

Treatment planning and aberration correction algorithm for HIFU ablation of renal tumors

PB Rosnitskiy, TD Khokhlova… - IEEE Transactions …, 2024 - ieeexplore.ieee.org
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of
renal tumors often encounter challenges due to significant beam aberration and refraction …

Shear wave elasticity imaging using nondiffractive Bessel apodized acoustic radiation force

F Feng, S Goswami, S Khan… - IEEE transactions on …, 2021 - ieeexplore.ieee.org
The acoustic radiation force impulse (ARFI) has been widely used in transient shear wave
elasticity imaging (SWEI). For SWEI based on focused ARFI, the highest image quality exists …

Measurement of the shear modulus in thin-layered tissues using numerical simulations and shear wave elastography

S Sadeghi, DH Cortes - Journal of the Mechanical Behavior of Biomedical …, 2020 - Elsevier
Measurement of mechanical properties of thin-layered tissues has broad applications in the
diagnosis of several pathologies. Ultrasound shear wave elastography (SWE) measures the …

Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD)

HP Wieser, Y Huang, J Schauer… - Physics in Medicine …, 2021 - iopscience.iop.org
Accurate knowledge of the exact stop** location of ions inside the patient would allow full
exploitation of their ballistic properties for patient treatment. The localized energy deposition …