Review of active power decoupling topologies in single-phase systems
Active power decoupling methods are developed to deal with the inherent ripple power at
twice the grid frequency in single-phase systems generally by adding active switches and …
twice the grid frequency in single-phase systems generally by adding active switches and …
Active Power-Decoupling Methods for Photovoltaic-Connected Applications: An Overview
This study compares ripple port, stacked switched capacitor, and capacitive energy storage
architectures for active power decoupling, comparing the number of components …
architectures for active power decoupling, comparing the number of components …
Capacitance, dc voltage utilizaton, and current stress: Comparison of double-line frequency ripple power decoupling for single-phase systems
Double-line frequency ripple power is inherent in single-phase rectifiers and inverters, and,
if not managed properly, it can be adverse to system performance at both the ac and dc …
if not managed properly, it can be adverse to system performance at both the ac and dc …
A single-phase inverter/rectifier topology with suppressed double-frequency ripple
K Mozaffari, M Amirabadi… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
This paper introduces a new bidirectional single-phase inverter topology. The proposed
topology has three ports: a dc port, an ac port, and a ripple port. The ac and dc ports are …
topology has three ports: a dc port, an ac port, and a ripple port. The ac and dc ports are …
A comprehensive review of single-phase converter topologies with 2ω-ripple suppress
J Jiang, H Sun, H Wang - Electrical Engineering, 2024 - Springer
Single-phase converters are commonly used in small and medium power supply systems,
but their inherent 2ω-ripple power has a significant impact on system performance, including …
but their inherent 2ω-ripple power has a significant impact on system performance, including …
Model-free power control of front-end PFC AC/DC converter for on-board charger
L Cao, H Li, H Zhang - 2016 IEEE 8th International Power …, 2016 - ieeexplore.ieee.org
In a two-stage on-board charger, the front-end PFC AC/DC converter with conventional dual
closed-loop PI controller, which consists of a external voltage loop and a inner current loop …
closed-loop PI controller, which consists of a external voltage loop and a inner current loop …
Power decoupling control for single-stage on-board chargers
Power density and efficiency are main specifications of on-board chargers (OBC) for electric
vehicles (EV). Single-stage OBCs are advantageous in terms of efficiency and cost, while …
vehicles (EV). Single-stage OBCs are advantageous in terms of efficiency and cost, while …
A soft-switching on-board charger for electric vehicle application
A Wei, B Lehman, M Amirabadi - 2024 IEEE Energy …, 2024 - ieeexplore.ieee.org
On-board charging (OBC) system with single phase voltage source has been a trending
topic of research in electric vehicle application. However, handling the double line frequency …
topic of research in electric vehicle application. However, handling the double line frequency …
Control method for the Sheppard–Taylor PFC rectifier to reduce capacitance requirements
Sheppard-Taylor power factor correction (ST-PFC) rectifier could obtain a high power factor
due to its capability of overcoming the control detuning issue. However, it needs a bulky …
due to its capability of overcoming the control detuning issue. However, it needs a bulky …
A Hill-Climbing Optimization Approach for Closed-Loop Auto-Tuning of the Grid-Connected Ripple-Port Inverters
Single phase grid-tied inverters have a characteristic double frequency power ripple. Such
double frequency ripple could negatively impact the maximum power point tracking …
double frequency ripple could negatively impact the maximum power point tracking …