Derating of transformers under non‐linear load current and non‐sinusoidal voltage–an overview

J Faiz, M Ghazizadeh, H Oraee - IET Electric Power …, 2015 - Wiley Online Library
The increasing application of non‐linear loads in power system causes additional losses in
transformers resulting in premature damage. Manufactures and users of transformers realise …

Fibre Bragg Grating Sensors for Condition Monitoring of High-Voltage Assets: A Review

V Ramnarine, V Peesapati, S Djurović - Energies, 2023 - mdpi.com
The high-voltage (HV) assets in the existing power transmission network will experience
increased electrical, thermal, environmental and mechanical stresses and, therefore, robust …

Insulation degradation and fracture cracks of mechanical impacted thermal‐ageing oil‐impregnated papers

M Chi, R **a, Y Guan, W Sun, J Liu, Q Chen - High Voltage, 2023 - Wiley Online Library
In order to elucidate mechanical impacts affecting the insulation strength of thermal‐ageing
oil‐impregnated pressboards, we perform mechanical degradation experiments of impacting …

Short-circuit electromagnetic force distribution characteristics in transformer winding transposition structures

Y Zhao, W Chen, M **, T Wen, J Xue… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
For continuous or spiral windings which feature multiple continuously transposed
conductors (CTC) wound in parallel, the transposition structure is commonly used to …

Identification of power transformer winding mechanical fault types based on online IFRA by support vector machine

Z Zhao, C Tang, Q Zhou, L Xu, Y Gui, C Yao - Energies, 2017 - mdpi.com
A transformer is the most valuable and expensive property for power utility, thus ensuring its
reliable operation is a major task for both operators and researchers. Online impulse …

Impacts of ferroresonance and inrush current forces on transformer windings

M Mikhak‐Beyranvand, B Rezaeealam… - IET Electric Power …, 2019 - Wiley Online Library
Deformation of the windings is one of the main causes of the power transformers failure.
Here, for the first time, the electromagnetic forces exerted on the windings are computed in …

Derating of distribution transformers under non‐linear loads using a combined analytical‐finite elements approach

M Ghazizadeh, J Faiz, H Oraee - IET Electric Power …, 2016 - Wiley Online Library
Supplying non‐linear loads causes increased losses in transformers which eventually leads
to their reduced life spans. Therefore, transformers are derated in order to protect them …

Copper pipes as medium frequency transformer windings

N Djekanovic, D Dujic - IEEE Access, 2022 - ieeexplore.ieee.org
Owing to increasing power demand, new technologies, such as solid-state transformers, are
progressively researched and improved. Thereby, galvanic isolation and voltage adaptation …

Investigation of electromagnetic forces in converter transformer

JU Kothavade, P Kundu - 2021 IEEE 2nd International …, 2021 - ieeexplore.ieee.org
In transient conditions, electromagnetic forces are produced. Due to these forces, radial and
axial displacements in the winding and insulation damage occur. In this paper, short-circuit …

An algorithm for fast calculation of short circuit forces in high current busbars of electric arc furnace transformers based on method of images

M Moghaddami, A Moghadasi, AI Sarwat - Electric Power Systems …, 2016 - Elsevier
This paper proposes an algorithm for the calculation of short circuit forces on the high
current busbars of electric arc furnace (EAF) transformers based on the method of images …