New ground fault location approach for partially coupled transmission lines

F Abbasi, AA Abdoos, SM Hosseini… - Electric Power Systems …, 2023 - Elsevier
The technical requirements and environmental limitations increase utilizing both the parallel
and partially coupled transmission lines. However, it is very demanding to find the fault point …

A new method for fault location in special parallel lines called “stitched lines”

M Gil, MM Mobashsher, AA Abdoos - Electric Power Systems Research, 2024 - Elsevier
Today, a special kind of parallel double-circuit line, designated" stitched lines," is employed
in various transmission and sub-distribution networks in some countries, like Iran. In this type …

An interpretative fault location and section identification algorithm for a three-terminal non-homogeneous transmission network

PR Chegireddy, R Bhimasingu - Electrical engineering, 2023 - Springer
Due to their accurate time stam**, phasor measurement units (PMUs) are being used for
the modern day power grid protection applications. As PMUs provide synchronous data, so …

[HTML][HTML] A distance protection approach for untransposed parallel transmission lines in case of phase-phase-ground inter-circuit faults

H Abdollahzadeh - International journal of electrical power & energy …, 2023 - Elsevier
Distance relays' phase and ground elements at either circuits of the parallel transmission
lines undergo miscalculation of the correct fault impedance when facing inter-circuit faults …

[HTML][HTML] Improved protection scheme for shipboard microgrids based on high frequency impedance method with experimental validation

AM Aboelezz, MM El-Saadawi, AA Eladl… - International Journal of …, 2025 - Elsevier
This paper addresses the critical problem of fault detection in DC zonal shipboard
microgrids, which is essential for ensuring system reliability and operational safety. The …

Fault distance measurement method for wind power transmission lines based on improved NSGA II

E Qi, Q Zhang, G Liu, Z Zhang, M Wang… - Engineering …, 2024 - iopscience.iop.org
A fault distance measurement method that is suitable for long-distance wind power
transmission lines is proposed by this paper. By combining the voltage and current at both …

Novel fault location method for double-circuit three-terminal lines

F Abbasi, SM Hosseini, AA Abdoos, M Sanaye-Pasand - Measurement, 2025 - Elsevier
This paper presents a new fault location method for double-circuit three-terminal lines based
on the negative sequence network. The proposed method utilizes local voltage and current …

Parameter-Less Fault Locator for Double-Circuit Transmission Line Using Two-Terminal Unsynchronized Measurements

A Saber, HH Zeineldin… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
This paper develops a parameter-free fault location (FL) method for double-circuit
transmission lines utilizing pre-and post-fault unsynchronized current and voltage …

Enhancing Prony's method for fault location

I Džafić, RA Jabr, N Čolo - International Journal of Electrical Power & …, 2022 - Elsevier
The paper presents a phasor estimator combining Prony's method and discrete analytic
signal generation for use in impedance-based fault location. The precision of impedance …

Analysis of transmission-line faults and auto recloser based protection

SF Moula, MT Ahammed - 2021 4th International Conference …, 2022 - ieeexplore.ieee.org
There is a need for transmission and distribution to supply high-quality, dependable
electricity to customers. The detection of transmission line problems must be more precise …