Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Lessons learnt from the recent EURADOS intercomparisons in computational dosimetry
Abstract Organized by Working Group 6 “Computational Dosimetry” of the European
Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was …
Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was …
Development and validation of the low‐cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy
Abstract Background Monte Carlo (MC) simulations or measurements in anthropomorphic
phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy …
phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy …
Practical overview of the ICRP Publication 145 phantoms for use with MCNP
L Hetrick, J Douglas, D Poudel - Radiation protection dosimetry, 2023 - academic.oup.com
This paper provides a practical overview of the mesh-type reference phantoms (MRCPs)
published by the ICRP by providing supplementary guidance on the proper implementation …
published by the ICRP by providing supplementary guidance on the proper implementation …
Significance and feasibility of air kerma length product and air kerma area product comparisons
Air kerma length product and air kerma area product are special quantities used in
diagnostic radiology. They are measured using special measurement devices–CT …
diagnostic radiology. They are measured using special measurement devices–CT …
A dosimetric comparison between ICRP and ORNL phantoms from exposure to 137Cs contaminated soil
The 137 Cs soil contamination has detrimental effects on human health. The penetration
and distribution of 137 Cs radionuclides at different soil depths were investigated. Two …
and distribution of 137 Cs radionuclides at different soil depths were investigated. Two …
Direct Monitoring Method to Detect Internal Radioactive Contamination
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …
method used for assessment of internal dose. It is used for estimation of organ/whole body …
[PDF][PDF] Расчет дозы облучения с использованием воксельных фантомов по программе MCU
ЮС Дайченкова, МЮ Никулин… - … атомной науки и …, 2023 - researchgate.net
Аннотация По прецизионной программе MCU, реализующей метод Монте-Карло,
выполнено моделирование расчетных бенчмарк-экспериментов, разработанных …
выполнено моделирование расчетных бенчмарк-экспериментов, разработанных …
EURADOS working group 6, computational dosimetry, a history of promoting good practice via intercomparisons and training
This paper is the editorial of a special issue of Radiation Measurements on EURADOS
intercomparisons in computational dosimetry. The articles in this special issue cover …
intercomparisons in computational dosimetry. The articles in this special issue cover …
Calculation of X-Ray Dose Loads in the Human Body Using Voxel Phantoms and the MCU Program
A benchmark experiment modeling two typical medical x-ray procedures–chest and
abdominal x-rays–was calculated for the purpose of verifying the MCU computer program for …
abdominal x-rays–was calculated for the purpose of verifying the MCU computer program for …
[PDF][PDF] Author's version
MY Nikulin, DS Oleynik, GS Sergeev… - Atomic …, 2023 - researchgate.net
Golem Laura Height, m................ 1.76........... 1.63 Weight, kg................ 73............ 60 Number of
tissue voxels........ 1,946,375........ 3,886,020 Total number of voxels......... 7,161,276 …
tissue voxels........ 1,946,375........ 3,886,020 Total number of voxels......... 7,161,276 …