[HTML][HTML] Pros and cons of ultra-high-field MRI/MRS for human application
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both
for clinical diagnostic applications and in basic research areas such as cognitive …
for clinical diagnostic applications and in basic research areas such as cognitive …
7 Tesla and beyond: advanced methods and clinical applications in magnetic resonance imaging
Ultrahigh magnetic fields offer significantly higher signal-to-noise ratio, and several
magnetic resonance applications additionally benefit from a higher contrast-to-noise ratio …
magnetic resonance applications additionally benefit from a higher contrast-to-noise ratio …
[HTML][HTML] In-vivo 31P-MRS of skeletal muscle and liver: a way for non-invasive assessment of their metabolism
In addition to direct assessment of high energy phosphorus containing metabolite content
within tissues, phosphorus magnetic resonance spectroscopy (31 P-MRS) provides options …
within tissues, phosphorus magnetic resonance spectroscopy (31 P-MRS) provides options …
The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review
With the increasing availability of ultra-high field MRI systems, studying non-proton nuclei (X-
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential
AL Lopez Kolkovsky, PG Carlier, B Marty… - NMR in …, 2022 - Wiley Online Library
Magnetic resonance signals from different nuclei can be excited or received at the same
time, rendering simultaneous or rapidly interleaved multi‐nuclear acquisitions feasible. The …
time, rendering simultaneous or rapidly interleaved multi‐nuclear acquisitions feasible. The …
Combining phase images from array coils using a short echo time reference scan (COMPOSER)
Purpose To develop a simple method for combining phase images from multichannel coils
that does not require a reference coil and does not entail phase unwrap**, fitting or …
that does not require a reference coil and does not entail phase unwrap**, fitting or …
Correlation between skeletal muscle acetylcarnitine and phosphocreatine metabolism during submaximal exercise and recovery: interleaved 1H/31P MRS 7 T study
Acetylcarnitine is an essential metabolite for maintaining metabolic flexibility and glucose
homeostasis. The in vivo behavior of muscle acetylcarnitine content during exercise has not …
homeostasis. The in vivo behavior of muscle acetylcarnitine content during exercise has not …
Dynamic 31P–MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T
Abstract Phosphorus MRSI (31P–MRSI) using a spiral‐trajectory readout at 7 T was
developed for high temporal resolution map** of the mitochondrial capacity of exercising …
developed for high temporal resolution map** of the mitochondrial capacity of exercising …
Interleaved 31P MRS/1H ASL for analysis of metabolic and functional heterogeneity along human lower leg muscles at 7T
Purpose MR offers the unique possibility to noninvasively investigate cellular energy
metabolism via 31P MRS, while blood perfusion, which provides oxygen and substrates to …
metabolism via 31P MRS, while blood perfusion, which provides oxygen and substrates to …
Simultaneous and interleaved acquisition of NMR signals from different nuclei with a clinical MRI scanner
Purpose Modification of a clinical MRI scanner to enable simultaneous or rapid interleaved
acquisition of signals from two different nuclei. Methods A device was developed to modify …