Impact of the latest generation of Josephson voltage standards in ac and dc electric metrology

A Rüfenacht, NE Flowers-Jacobs, SP Benz - Metrologia, 2018 - iopscience.iop.org
For decades, the quantum behavior of Josephson junctions has been employed as intrinsic
standards for voltage metrology. Conventional dc Josephson voltage standards have been …

The ampere and the electrical units in the quantum era

W Poirier, S Djordjevic, F Schopfer… - Comptes Rendus Physique, 2019 - Elsevier
By fixing two fundamental constants from quantum mechanics, the Planck constant h and the
elementary charge e, the revised “Système international”(SI) of units endorses explicitly …

Precision sampling measurements using ac programmable Josephson voltage standards

A Rüfenacht, CJ Burroughs, SP Benz - Review of Scientific Instruments, 2008 - pubs.aip.org
We have performed a variety of precision measurements by comparing ac and dc
waveforms generated by two independent ac programmable Josephson voltage standard …

Uncertainty evaluation of a 10 V rms sampling measurement system using the AC programmable Josephson voltage standard

SF Chen, Y Amagai, M Maruyama… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
We have evaluated the uncertainty in the differential sampling measurement of the RMS
amplitude of 10 V waveform synthesis based on an AC programmable Josephson voltage …

A water calorimeter for on-site absorbed dose to water calibrations in 60Co and MV-photon beams including MRI incorporated treatment equipment

L De Prez, J De Pooter, B Jansen… - Physics in Medicine & …, 2016 - iopscience.iop.org
In reference dosimetry the aim is to establish the absorbed dose to water, D w, under
reference conditions. However, existing dosimetry protocols are not always applicable for …

Josephson-voltage-standard-locked sine wave synthesizer: Margin evaluation and stability

B Jeanneret, F Overney, L Callegaro… - IEEE Transactions …, 2008 - ieeexplore.ieee.org
This paper describes a Josephson-voltage-standard-locked synthesizer where a
commercial digital-to-analog converter is used as a sine wave generator. The output …

Differential Sampling of AC Waveforms Based on a Commercial Digital-to-Analog Converter for Reference

Y Wang, X Sun, J Zhao, K Zhou, Y Lu, J Qu, P Hu, Q He - Sensors, 2024 - mdpi.com
This paper introduces an innovative differential sampling technique for calibrating AC
waveforms, leveraging a commercially available 16-bit digital-to-analog converter (DAC) as …

Automated direct comparison of two cryocooled 10 volt programmable Josephson voltage standards

A Rüfenacht, Y Tang, S Solve, AE Fox… - Metrologia, 2018 - iopscience.iop.org
We have performed direct dc comparisons between two cryocooled 10 V programmable
Josephson voltage standards. Utilizing an automated synchronization scheme for the …

Influence of sampling voltmeter parameters on RMS measurements of Josephson stepwise-approximated sine waves

HE van den Brom, E Houtzager… - IEEE Transactions …, 2009 - ieeexplore.ieee.org
A binary Josephson-array voltage standard was used to investigate the influence of device
settings on the reading of an 81/2-digit sampling voltmeter. This voltmeter is the heart of the …

Evaluation of linearity characteristics in digital voltmeters using a PJVS system with a 10-K cooler

M Maruyama, H Takahashi, K Katayama… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
We have evaluated the linearity of commercial digital voltmeters (DVMs) using a
programmable Josephson voltage standard (PJVS) system. The PJVS system is composed …