Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Characterization and performance of co-axial HPGe detectors
High purity germanium (HPGe) detectors are deployed globally for gamma-radiation
spectroscopy due to their superior energy resolution. In this work, the essential …
spectroscopy due to their superior energy resolution. In this work, the essential …
Calibration of а single hexagonal NaI (Tl) detector using a new numerical method based on the efficiency transfer method
Gamma-ray detector systems are important instruments in a broad range of science and new
setup are continually develo**. The most recent step in the evolution of detectors for …
setup are continually develo**. The most recent step in the evolution of detectors for …
New analytical approach to calibrate the NaI (Tl) detectors using spherical radioactive sources
A new theoretical approach was used to calibrate and calculate the full-energy peak
efficiency of the NaI (Tl) detectors based on the direct statistical method proposed by Selim …
efficiency of the NaI (Tl) detectors based on the direct statistical method proposed by Selim …
New analytical approach to calibrate the co-axial HPGe detectors including correction for source matrix self-attenuation
To calibrate the co-axial HPGe semiconductor detectors, we introduce a new theoretical
approach based on the Direct Statistical method proposed by Selim and Abbas (1995, 1996) …
approach based on the Direct Statistical method proposed by Selim and Abbas (1995, 1996) …
New algorithm for studying the effect of self attenuation factor on the efficiency of γ-rays detectors
A new analytical approach is introduced to calculate the full-energy peak efficiency of co-
axial HPGe semiconductor detectors, including the source (with a radius smaller than …
axial HPGe semiconductor detectors, including the source (with a radius smaller than …
A new analytical method to calibrate cylindrical phoswich and LaBr3 (Ce) scintillation detectors
MI Abbas - Nuclear Instruments and Methods in Physics Research …, 2010 - Elsevier
A new analytical method of efficiency calibration is proposed for cylindrical phoswich and
lanthanum bromide (LaBr3: Ce) scintillation detectors. This method depends on the accurate …
lanthanum bromide (LaBr3: Ce) scintillation detectors. This method depends on the accurate …
[HTML][HTML] Determination of full energy peak efficiency of NaI (Tl) detector depending on efficiency transfer principle for conversion form experimental values
M Abd-Elzaher, MS Badawi, A El-Khatib, AA Thabet - 2012 - scirp.org
In this work we calibrated the NaI (Tl) scintillation detectors (5.08× 5.08 cm2 and 7.62× 7.62
cm2) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated …
cm2) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated …
Analytical approach to calculate the efficiency of 4π NaI (Tl) gamma-ray detectors for extended sources
MI Abbas - Nuclear Instruments and Methods in Physics Research …, 2010 - Elsevier
The 4π NaI (Tl) detectors are usually utilized for low-level radioactivity measurements of
environmental samples in gamma-ray spectroscopy due to the near 4π solid angle and high …
environmental samples in gamma-ray spectroscopy due to the near 4π solid angle and high …
Systematic study of (,) reaction cross sections from the reaction threshold to 20 MeV
The cross sections of nat Cr (n, x) 52 V, 52 Cr (n, p) 52 V, nat Cr (n, x) 53 V, 53 Cr (n, p) 53 V,
nat Zn (n, x) 66 Cu, 66 Zn (n, p) 66 Cu, nat Zn (n, x) 68 Cu m, 68 Zn (n, p) 68 Cu m, nat Mo (n …
nat Zn (n, x) 66 Cu, 66 Zn (n, p) 66 Cu, nat Zn (n, x) 68 Cu m, 68 Zn (n, p) 68 Cu m, nat Mo (n …
Efficiency calibration of -ray detector for extended sources
Precise identification and quantification of radioisotope in a sample largely depend on the
accuracy of the full-energy peak efficiency of the detector. It is generally observed that the …
accuracy of the full-energy peak efficiency of the detector. It is generally observed that the …