Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Hydrogels for three-dimensional ionizing-radiation dosimetry
M Marrale, F d'Errico - Gels, 2021 - mdpi.com
Radiation-sensitive gels are among the most recent and promising developments for
radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality …
radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality …
[HTML][HTML] How xylenol orange and ferrous ammonium sulphate influence the dosimetric properties of PVA–GTA Fricke gel dosimeters: A spectrophotometric study
M Scotti, P Arosio, E Brambilla, S Gallo, C Lenardi… - Gels, 2022 - mdpi.com
The development of Fricke gel (FG) dosimeters based on poly (vinyl alcohol)(PVA) as the
gelling agent and glutaraldehyde (GTA) as the cross-linker has enabled significant …
gelling agent and glutaraldehyde (GTA) as the cross-linker has enabled significant …
Improvement on the performance of chemically cross-linked fricke methylthymol-blue radiochromic gel dosimeter by addition of dimethyl sulfoxide
The effect of free radical scavenger dimethyl sulfoxide (DMSO) on the performance of
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
Does the gelation temperature or the sulfuric acid concentration influence the dosimetric properties of radiochromic PVA-GTA Xylenol Orange Fricke gels?
Purpose of this study is to test if possible effects of gelation temperature and pH on the cross-
linking process between poly (vinyl alcohol)(PVA) and glutaraldehyde (GTA), have …
linking process between poly (vinyl alcohol)(PVA) and glutaraldehyde (GTA), have …
Temperature behavior of radiochromic poly (vinyl-alcohol)-glutaraldehyde Fricke gel dosimeters in practice
The use of synthetic gel matrices prepared with poly (vinyl-alcohol)(PVA) cross-linked by
glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel …
glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel …
High optical stability of reusable radiochromic polyvinyl alcohol-iodine gel dosimeter for radiotherapy
In this study, a stable reusable radio-chromic gel dosimeter based on a polyvinyl alcohol-
sodium iodide complexes (PVA-NaI) and chemical cross-linking agent glutaraldehyde …
sodium iodide complexes (PVA-NaI) and chemical cross-linking agent glutaraldehyde …
Characterization of radiochromic poly (vinyl-alcohol)–glutaraldehyde Fricke gels for dosimetry in external x-ray radiation therapy
S Gallo, E Artuso, MG Brambilla… - Journal of Physics D …, 2019 - iopscience.iop.org
Quality assurance procedures required in modern radiotherapy would greatly benefit from
the development of tissue equivalent dosimeters able to render three-dimensional dose …
the development of tissue equivalent dosimeters able to render three-dimensional dose …
Effect of ionizing radiation on the colorimetric properties of PVA-GTA Xylenol Orange Fricke gel dosimeters
S Gallo, S Pasquale, C Lenardi, I Veronese, AM Gueli - Dyes and Pigments, 2021 - Elsevier
Fricke gel dosimeters were prepared using a matrix based on poly (vinyl-alcohol) chemical
cross-linked with glutaraldehyde and loaded with Xylenol Orange. The samples were …
cross-linked with glutaraldehyde and loaded with Xylenol Orange. The samples were …
Nuclear magnetic resonance analysis of a chemically cross-linked ferrous–methylthymol blue–polyvinyl alcohol radiochromic gel dosimeter
A new formulation of hydrogel dosimeter consisting of ferrous–methylthymol blue (MTB)–
polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and …
polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and …
Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques
S Gallo, L Cremonesi, G Gambarini, L Ianni… - Sensors and Actuators B …, 2018 - Elsevier
Optical absorbance and dynamic light scattering studies of Fricke xylenol orange gel
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …