Review of active power decoupling topologies in single-phase systems
Active power decoupling methods are developed to deal with the inherent ripple power at
twice the grid frequency in single-phase systems generally by adding active switches and …
twice the grid frequency in single-phase systems generally by adding active switches and …
Control schemes for reducing second harmonic current in two-stage single-phase converter: An overview from DC-bus port-impedance characteristics
L Zhang, X Ruan - IEEE Transactions on Power Electronics, 2019 - ieeexplore.ieee.org
The instantaneous input and output power of two-stage single-phase converter are
imbalanced, resulting in the second harmonic current (SHC) in the dc-dc converter, dc …
imbalanced, resulting in the second harmonic current (SHC) in the dc-dc converter, dc …
An overview of capacitive dc-links-topology derivation and scalability analysis
Capacitive dc-links are widely used in voltage source converters for power balance, voltage
ripple limitation, and short-term energy storage. A typical solution, which uses aluminum …
ripple limitation, and short-term energy storage. A typical solution, which uses aluminum …
LED systems applications and LED driver topologies: A review
High-power light-emitting diodes (LEDs) and high-brightness LEDs have revolutionized the
lighting industry. The availability of cost-effective LEDs with high luminous flux, efficacy, and …
lighting industry. The availability of cost-effective LEDs with high luminous flux, efficacy, and …
Review and comparison of control strategies in active power decoupling
The active power-decoupling (APD) method is an effective solution to handle the inherent
double-line frequency ripple power in single-phase power systems. It removes the bulky …
double-line frequency ripple power in single-phase power systems. It removes the bulky …
Second-harmonic current reduction for two-stage inverter with boost-derived front-end converter: Control schemes and design considerations
L Zhang, X Ruan, X Ren - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
The instantaneous output power of the two-stage single-phase inverter pulsates at twice the
output frequency (2f o), generating notorious second-harmonic current (SHC) in the frontend …
output frequency (2f o), generating notorious second-harmonic current (SHC) in the frontend …
Benchmark of AC and DC active power decoupling circuits for second-order harmonic mitigation in kilowatt-scale single-phase inverters
This paper presents the benchmark study of ac and dc active power decoupling (APD)
circuits for the second-order harmonic mitigation in kilowatt-scale single-phase inverters …
circuits for the second-order harmonic mitigation in kilowatt-scale single-phase inverters …
Activation of the catalytic activity of thrombin for fibrin formation by ultrasound
The regulation of enzyme activity is a method to control biological function. We report two
systems enabling the ultrasound‐induced activation of thrombin, which is vital for secondary …
systems enabling the ultrasound‐induced activation of thrombin, which is vital for secondary …
Onboard battery chargers for plug-in electric vehicles with dual functional circuit for low-voltage battery charging and active power decoupling
This paper proposes a single-phase onboard battery charger (OBC) for plug-in electric
vehicles, where the low-voltage (LV) battery charging circuit is utilized for an active power …
vehicles, where the low-voltage (LV) battery charging circuit is utilized for an active power …
Inverter power control based on DC-link voltage regulation for IPMSM drives without electrolytic capacitors
N Zhao, G Wang, D Xu, L Zhu… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
DC-link electrolytic capacitor critically affects the lifetime of the motor drive system. This
paper proposes an inverter power control strategy based on dc-link voltage regulation for …
paper proposes an inverter power control strategy based on dc-link voltage regulation for …