Motion in radiotherapy: particle therapy
Charged particle beam radiotherapy requires dedicated measures to compensate for the
dosimetric influence of inter-and intra-fractional target motion. Independent of the delivery …
dosimetric influence of inter-and intra-fractional target motion. Independent of the delivery …
Recent advances and future progress in PET instrumentation
PJ Slomka, T Pan, G Germano - Seminars in nuclear medicine, 2016 - Elsevier
PET is an important and growing imaging modality. PET instrumentation has undergone a
steady evolution improving various aspects of imaging. In this review, we discuss recent and …
steady evolution improving various aspects of imaging. In this review, we discuss recent and …
The management of respiratory motion in radiation oncology report of AAPM Task Group 76 a
This document is the report of a task group of the AAPM and has been prepared primarily to
advise medical physicists involved in the external‐beam radiation therapy of patients with …
advise medical physicists involved in the external‐beam radiation therapy of patients with …
Respiratory correlated cone beam CT
A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is
a powerful tool for image guided radiotherapy. Respiratory motion, however, induces …
a powerful tool for image guided radiotherapy. Respiratory motion, however, induces …
The management of imaging dose during image‐guided radiotherapy: report of the AAPM Task Group 75
MJ Murphy, J Balter, S Balter, JA BenComo Jr… - Medical …, 2007 - Wiley Online Library
Radiographic image guidance has emerged as the new paradigm for patient positioning,
target localization, and external beam alignment in radiotherapy. Although widely varied in …
target localization, and external beam alignment in radiotherapy. Although widely varied in …
4D‐CT imaging of a volume influenced by respiratory motion on multi‐slice CT
We propose a new scanning protocol for generating 4D‐CT image data sets influenced by
respiratory motion. A cine scanning protocol is used during data acquisition, and two …
respiratory motion. A cine scanning protocol is used during data acquisition, and two …
Classification and evaluation strategies of auto‐segmentation approaches for PET: Report of AAPM task group No. 211
Purpose The purpose of this educational report is to provide an overview of the present state‐
of‐the‐art PET auto‐segmentation (PET‐AS) algorithms and their respective validation, with …
of‐the‐art PET auto‐segmentation (PET‐AS) algorithms and their respective validation, with …
Four‐dimensional computed tomography: image formation and clinical protocol
E Rietzel, T Pan, GTY Chen - Medical physics, 2005 - Wiley Online Library
Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans
as commonly used for treatment planning can include severe motion artifacts that result from …
as commonly used for treatment planning can include severe motion artifacts that result from …
4D MR imaging of respiratory organ motion and its variability
M von Siebenthal, G Szekely, U Gamper… - Physics in Medicine …, 2007 - iopscience.iop.org
This paper describes a method for 4D imaging, which is used to study respiratory organ
motion, a key problem in various treatments. Whilst the commonly used imaging methods …
motion, a key problem in various treatments. Whilst the commonly used imaging methods …
Acquiring 4D thoracic CT scans using a multislice helical method
PJ Keall, G Starkschall, HEE Shukla… - Physics in Medicine …, 2004 - iopscience.iop.org
Respiratory motion degrades anatomic position reproducibility during imaging, necessitates
larger margins during radiotherapy planning and causes errors during radiation delivery …