Tuned‐TSC based SVC for reactive power compensation and harmonic reduction in unbalanced distribution system

S Das, D Chatterjee… - … Transmission & Distribution, 2018 - Wiley Online Library
A reactive power compensation scheme along with harmonic reduction technique for an
unbalanced four‐wire system has been addressed in this study. The proposed …

A GSA-based modified SVC switching scheme for load balancing and source power factor improvement

S Das, D Chatterjee… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
An improved switching scheme for static VAr compensators (SVCs) that have fixed capacitor-
thyristor-controlled reactors (FC-TCRs) for load balancing and power factor improvement …

Characteristics of the magnetic energy recovery switch as a static Var compensator technology

M Cheng, K Feng, T Isobe, R Shimada - IET Power Electronics, 2015 - Wiley Online Library
The magnetic energy recovery switch (MERS) has been proposed as a new reactive power
compensator. It has been proven by some series compensation applications. In terms of …

A novel compensation scheme based on a virtual air gap variable reactor for AC voltage control

J Avila-Montes, D Campos-Gaona… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
Voltage control based on reactive power compensation is a fundamental aspect of the
operation of ac electric power systems. This paper presents a novel shunt compensation …

[PDF][PDF] Optimal design of TCR/FC in electric arc furnaces for power quality improvement in power systems

RA Hooshmand, MT Esfahani - Leonardo Electronic Journal of …, 2009 - researchgate.net
Abstract Electric Arc Furnaces (EAFs) are unbalanced, nonlinear and time varying loads,
which can cause many problems in the power system quality. As the use of arc furnace …

Reactive power compensation in a steel industrial plant with several operating electric arc furnaces utilizing open‐loop controlled TCR/FC compensators

AD Kolagar, A Kiyoumarsi, M Ataei… - … on Electrical Power, 2011 - Wiley Online Library
Electric arc furnaces (EAFs) produce voltage fluctuations and flicker because of the reactive
power severe variations. Furthermore, these loads absorb a large amount of reactive power …

Bibliography of FACTS: 2006–2007 Part I IEEE working group report

RK Varma, I Axente… - IEEE PES General …, 2010 - ieeexplore.ieee.org
This paper presents a Bibliography of FACTS technology mainly for the year 2007. Papers
published/presented in Conferences in later part of 2006, which appeared on search …

Investigation of control processes in the electric network with static var compensator

SI Malafeev, AA Malafeeva - 2021 International Conference on …, 2021 - ieeexplore.ieee.org
In this work we propose investigation of electric power processes, including energy
recuperation, in the electric network with a thyristor-reactor VAr compensator under various …

[PDF][PDF] Tristör Kontrollü Reaktörün Sinirsel Bulanık Denetim Esaslı Reaktif Güç Kontrolü

ÖF Keçecioğlu, E Kılıç - Gazi University Journal of Science Part C …, 2019 - dergipark.org.tr
Bu çalışmada, esnek aa iletim sistemi cihazlarının ana elemanlarından biri olan tristör
kontrollü reaktörün sinirsel bulanık denetim esaslı reaktif güç kontrolü yapılmıştır. Sinirsel …

Thyristor controlled LC compensator for current harmonic reduction

SR Gaigowal, S Bhongade… - Recent Advances in …, 2023 - taylorfrancis.com
Modern power system requires control on all the power system parameters like bus volage,
power angle and line reactance. Flexible alternating current transmission system (FACTS) …