The synchronization of chaotic systems
Synchronization of chaos refers to a process wherein two (or many) chaotic systems (either
equivalent or nonequivalent) adjust a given property of their motion to a common behavior …
equivalent or nonequivalent) adjust a given property of their motion to a common behavior …
Physics with electrostatic rings and traps
The recent development of electrostatic devices which allow us to store keV ion beams has
launched several new kinds of investigations. We review the basic ideas behind the …
launched several new kinds of investigations. We review the basic ideas behind the …
Higher resolution charge detection mass spectrometry
AR Todd, LF Barnes, K Young, A Zlotnick… - Analytical …, 2020 - ACS Publications
Charge detection mass spectrometry is a single particle technique where the masses of
individual ions are determined from simultaneous measurements of each ion'sm/z ratio and …
individual ions are determined from simultaneous measurements of each ion'sm/z ratio and …
[HTML][HTML] Increased beam energy as a pathway towards a highly selective and high-flux MR-ToF mass separator
Many experiments at radioactive ion beam (RIB) facilities suffer from isobaric contamination,
ie unwanted ions of similar mass. During the last decade, Multi-Reflection Time-of-Flight …
ie unwanted ions of similar mass. During the last decade, Multi-Reflection Time-of-Flight …
Charge detection mass spectrometry for single ions with a limit of detection of 30 charges
NC Contino, MF Jarrold - International Journal of Mass Spectrometry, 2013 - Elsevier
A charge detection mass spectrometer (CDMS) with a limit of detection of 30 elementary
charges (e) for a single ion is described. The new CDMS consists of an electrospray source …
charges (e) for a single ion is described. The new CDMS consists of an electrospray source …
Electrostatic Linear Ion Trap Optimization Strategy for High Resolution Charge Detection Mass Spectrometry
DY Botamanenko, DW Reitenbach… - Journal of the …, 2023 - ACS Publications
Single ion mass measurements allow mass distributions to be recorded for heterogeneous
samples that cannot be analyzed by conventional mass spectrometry. In charge detection …
samples that cannot be analyzed by conventional mass spectrometry. In charge detection …
Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle‐in‐cell approach
Abstract Using a 'Particle‐In‐Cell'approach taken from plasma physics we have developed a
new three‐dimensional (3D) parallel computer code that today yields the highest possible …
new three‐dimensional (3D) parallel computer code that today yields the highest possible …
A cryogenic electrostatic trap for long-time storage of keV ion beams
M Lange, M Froese, S Menk, J Varju… - Review of Scientific …, 2010 - pubs.aip.org
We report on the realization and operation of a fast ion beam trap of the linear electrostatic
type employing liquid helium cooling to reach extremely low blackbody radiation …
type employing liquid helium cooling to reach extremely low blackbody radiation …
A multi-reflection time-of-flight mass separator for isobaric purification of radioactive ion beams
A multi-reflection time-of-flight mass separator (MR-ToF-MS) for the enhancement of the
performance of the Penning-trap mass spectrometer ISOLTRAP at the on-line isotope …
performance of the Penning-trap mass spectrometer ISOLTRAP at the on-line isotope …
Diffusion and synchronization in an ion-trap resonator
The motion of an ion bunch trapped between two electrostatic mirrors in an ion-trap
resonator is analyzed both experimentally and via numerical simulations. It is found that …
resonator is analyzed both experimentally and via numerical simulations. It is found that …