Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A review of high-frequency ultrasonic transducers for photoacoustic imaging applications
Photoacoustic imaging (PAI) is a new and rapidly growing hybrid biomedical imaging
modality that combines the virtues of both optical and ultrasonic (US) imaging. The nature of …
modality that combines the virtues of both optical and ultrasonic (US) imaging. The nature of …
[HTML][HTML] Mechanically rotating intravascular ultrasound (IVUS) transducer: a review
JH Sung, JH Chang - Sensors, 2021 - mdpi.com
Intravascular ultrasound (IVUS) is a valuable imaging modality for the diagnosis of
atherosclerosis. It provides useful clinical information, such as lumen size, vessel wall …
atherosclerosis. It provides useful clinical information, such as lumen size, vessel wall …
Design and fabrication of non-periodic 1–3 composite structure for ultrasonic transducer application
P Lin, Y Zhu, Z Chen, C Fei, D Chen, S Zhang, D Li… - Composite …, 2022 - Elsevier
Piezoelectric composite materials (PCMs), combing the advantages of both piezoelectric
materials and polymers, have been extensively used in piezoelectric material ultrasonic …
materials and polymers, have been extensively used in piezoelectric material ultrasonic …
Investigation of cross-coupling in piezoelectric transducer arrays and correction
Cross-coupling in piezoelectric transducer arrays is an undesirable phenomenon which
decreases the performance of these devices. Indeed, when one element of a transducer is …
decreases the performance of these devices. Indeed, when one element of a transducer is …
Design and Fabrication of Annular-Array Ultrasound Transducer Based (K, Na) NbO3 Lead-Free 1–3 Piezoelectric Composite
This article reports the design, fabrication, and performance of an annular-array ultrasound
transducer using (K, Na) NbO3 (KNN)-based lead-free 1–3 piezoelectric composite. The 1–3 …
transducer using (K, Na) NbO3 (KNN)-based lead-free 1–3 piezoelectric composite. The 1–3 …
An FPGA-based open platform for ultrasound biomicroscopy
Ultrasound biomicroscopy (UBM) has been extensively applied to preclinical studies in
small animal models. Individual animal study is unique and requires different utilization of …
small animal models. Individual animal study is unique and requires different utilization of …
Development of 15 MHz 2-2 piezo-composite ultrasound linear array transducers for ophthalmic imaging
JH Cha, JH Chang - Sensors and Actuators A: Physical, 2014 - Elsevier
Abstract High frequency (> 15 MHz) ultrasound imaging is capable of producing high spatial
resolution B-mode and color Doppler images for the efficient diagnosis of ocular diseases …
resolution B-mode and color Doppler images for the efficient diagnosis of ocular diseases …
A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite
JM Cannata, JA Williams, L Zhang… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
This paper describes the development of a highfrequency 256-element linear ultrasonic
array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were …
array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were …
Multiscale analysis of laminated plates with integrated piezoelectric fiber composite actuators
AC Cook, SS Vel - Composite Structures, 2012 - Elsevier
This study is concerned with the detailed analysis of fiber-reinforced composite plates with
integrated piezoceramic fiber composite actuators. A multiscale framework based on the …
integrated piezoceramic fiber composite actuators. A multiscale framework based on the …
Fabrication and characterization of a 20-MHz microlinear phased-array transducer for intervention guidance
This paper describes the design and fabrication of a miniature ultrasonic phased-array
transducer used for intervention guidance. Currently, ultrasound probes are often placed at …
transducer used for intervention guidance. Currently, ultrasound probes are often placed at …