Model-based dose calculation algorithms for brachytherapy dosimetry
The purpose of this study was to review the limitations of dose calculation formalisms for
photon-emitting brachytherapy sources based on the American Association of Physicists in …
photon-emitting brachytherapy sources based on the American Association of Physicists in …
On the fluid flow and heat transfer between a cone and a disk both stationary or rotating
M Turkyilmazoglu - Mathematics and Computers in Simulation, 2020 - Elsevier
The present paper investigates the role that the radial component of heat conduction plays
in a cone-plate viscometer. The cone and the disk may be taken as stationary or in action; …
in a cone-plate viscometer. The cone and the disk may be taken as stationary or in action; …
AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model‐based dose calculation algorithms in brachytherapy
The introduction of model‐based dose calculation algorithms (MBDCAs) in brachytherapy
provides an opportunity for a more accurate dose calculation and opens the possibility for …
provides an opportunity for a more accurate dose calculation and opens the possibility for …
A generic TG‐186 shielded applicator for commissioning model‐based dose calculation algorithms for high‐dose‐rate 192Ir brachytherapy
Purpose A joint working group was created by the American Association of Physicists in
Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the …
Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the …
Dose point kernels for 2,174 radionuclides
Purpose Rapid adoption of targeted radionuclide therapy as an oncologic intervention has
motivated the development of patient‐specific voxel‐wise approaches to radiation …
motivated the development of patient‐specific voxel‐wise approaches to radiation …
Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model‐based dose calculations
Abstract Purpose A joint Working Group of the American Association of Physicists in
Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the …
Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the …
Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer
We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-
dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer …
dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer …
Personalized Superficial HDR Brachytherapy—Dosimetric Verification of Dose Distribution with Lead Shielding of Critical Organs in the Head and Neck Region
G Zwierzchowski, G Bielęda, A Szymbor… - Journal of Personalized …, 2022 - mdpi.com
Background: Surface brachytherapy, usually characterized by a high dose gradient, allows
the dose to be precisely deposited in the irradiated area while protecting critical organs …
the dose to be precisely deposited in the irradiated area while protecting critical organs …
On the use of a novel Ferrous Xylenol-orange gelatin dosimeter for HDR brachytherapy commissioning and quality assurance testing
Purpose To evaluate a commercially available Ferrous-Xylenol Orange-Gel (FXG) dosimeter
(TrueView™) coupled with Optical-Computed Tomography (OCT) read out, for 3D dose …
(TrueView™) coupled with Optical-Computed Tomography (OCT) read out, for 3D dose …