Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A review of the developments of radioxenon detectors for nuclear explosion monitoring
Developments in radioxenon monitoring since the implementation of the International
Monitoring System are reviewed with emphasis on the most current technologies to improve …
Monitoring System are reviewed with emphasis on the most current technologies to improve …
Trends in nuclear explosion monitoring research & development-a physics perspective
M Maceira, PS Blom, JK MacCarthy, OE Marcillo… - 2017 - osti.gov
This document entitled “Trends in Nuclear Explosion Monitoring Research and
Development–A Physics Perspective” reviews the accessible literature, as it relates to …
Development–A Physics Perspective” reviews the accessible literature, as it relates to …
Development of a beta-gamma radioxenon detector with improved beta resolution
Abstract The International Monitoring System includes a network of radionuclide detectors
operated around the world monitoring for nuclear explosions. A key aspect of the …
operated around the world monitoring for nuclear explosions. A key aspect of the …
Japanese organic farmers: Strategies of uncertainty after the Fukushima disaster
N Rosenberger - Ethnos, 2016 - Taylor & Francis
This ethnographic study of organic farmers affected by radioactive contamination in Japan
illuminates responses to situated uncertainty as an everyday mode of subjectivity and …
illuminates responses to situated uncertainty as an everyday mode of subjectivity and …
A radioxenon detection system using PIPS and CZT
This paper introduces and describes the initial characterizations of a prototype beta-gamma
coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for …
coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for …
Radiation source localization using a model-based approach
A Molnár, D Kiss, Z Domozi - Sensors, 2023 - mdpi.com
The procedure is practically an optimization method, during which it is assumed that the
gamma dose values detected at different points above the area come from the background …
gamma dose values detected at different points above the area come from the background …
Stilbene cell development to improve radioxenon detection
A prototype stilbene beta cell has been designed, manufactured, tested, and compared to a
plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon …
plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon …
Implementation of Additional Beta–Gamma Detectors for Improved Radioxenon Laboratory Throughput
Abstract The International Monitoring System includes a network of radionuclide detector
stations and laboratories operated around the world monitoring for nuclear explosions. The …
stations and laboratories operated around the world monitoring for nuclear explosions. The …
Evaluating the intensity of the 'prompt'140.5 keV γ-ray of 99Mo using a 4παβ (LS)-γ (HPGe) measurement system
S Nissim, O Aviv, M Brandis, L Weissman… - Applied Radiation and …, 2022 - Elsevier
The absolute intensity for the 'prompt'140.5 keV gamma-ray of 99 Mo was evaluated using
the β-γ coincidence technique. A liquid sample of 99 Mo was prepared from a 99 Mo/99m Tc …
the β-γ coincidence technique. A liquid sample of 99 Mo was prepared from a 99 Mo/99m Tc …
Design and operation of the US Radionuclide Noble Gas Laboratory for the CTBTO
Abstract The International Monitoring System includes a network of radionuclide detectors
operated around the world monitoring for nuclear explosions. A key aspect of the …
operated around the world monitoring for nuclear explosions. A key aspect of the …