Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis
Purpose Although invasive intracranial devices (IIDs) are the gold standard for intracranial
pressure (ICP) measurement, ultrasonography of the optic nerve sheath diameter (ONSD) …
pressure (ICP) measurement, ultrasonography of the optic nerve sheath diameter (ONSD) …
Spontaneous intracranial hypotension: searching for the CSF leak
Spontaneous intracranial hypotension is caused by loss of CSF at the level of the spine. The
most frequent symptom of this disorder is orthostatic headache, with the headache …
most frequent symptom of this disorder is orthostatic headache, with the headache …
Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
Purpose To evaluate the diagnostic accuracy of ultrasonography of optic nerve sheath
diameter (ONSD) for assessment of intracranial hypertension. Methods Systematic review …
diameter (ONSD) for assessment of intracranial hypertension. Methods Systematic review …
Optic nerve ultrasound for the detection of raised intracranial pressure
V Rajajee, M Vanaman, JJ Fletcher, TL Jacobs - Neurocritical care, 2011 - Springer
Background Optic nerve ultrasonography (ONUS) may help identify raised intracranial
pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification …
pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification …
Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study
C Robba, D Cardim, T Tajsic, J Pietersen… - PLoS …, 2017 - journals.plos.org
Background The invasive nature of the current methods for monitoring of intracranial
pressure (ICP) has prevented their use in many clinical situations. Several attempts have …
pressure (ICP) has prevented their use in many clinical situations. Several attempts have …
Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography: a systematic review and meta …
Objectives The diagnosis of raised intracranial pressure (ICP) is important in many critically
ill patients. The optic nerve sheath is contiguous with the subarachnoid space; thus, an …
ill patients. The optic nerve sheath is contiguous with the subarachnoid space; thus, an …
Bedside optic nerve ultrasonography for diagnosing increased intracranial pressure: a systematic review and meta-analysis
Background: Optic nerve ultrasonography (optic nerve sheath diameter sonography) has
been proposed as a noninvasive, quick method for diagnosing increased intracranial …
been proposed as a noninvasive, quick method for diagnosing increased intracranial …
Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
BACKGROUND AND AIMS: An increase in the intracranial pressure (ICP) might aggravate
patient outcomes by inducing neurologic injuries. In patients with increased ICP the optic …
patient outcomes by inducing neurologic injuries. In patients with increased ICP the optic …
Intra‐and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults
J Bäuerle, P Lochner, M Kaps… - Journal of …, 2012 - Wiley Online Library
ABSTRACT BACKGROUND The use of an ultrasound‐based evaluation of the optic nerve
sheath diameter (ONSD) has previously been demonstrated for detecting raised intracranial …
sheath diameter (ONSD) has previously been demonstrated for detecting raised intracranial …
Non‐invasive assessment of intracranial pressure
C Robba, S Bacigaluppi, D Cardim… - Acta Neurologica …, 2016 - Wiley Online Library
Monitoring of intracranial pressure (ICP) is invaluable in the management of neurosurgical
and neurological critically ill patients. Invasive measurement of ventricular or parenchymal …
and neurological critically ill patients. Invasive measurement of ventricular or parenchymal …