Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Golden‐angle radial MRI: basics, advances, and applications
L Feng - Journal of Magnetic Resonance Imaging, 2022 - Wiley Online Library
In recent years, golden‐angle radial sampling has received substantial attention and interest
in the magnetic resonance imaging (MRI) community, and it has become a popular sampling …
in the magnetic resonance imaging (MRI) community, and it has become a popular sampling …
Compressed sensing for body MRI
The introduction of compressed sensing for increasing imaging speed in magnetic
resonance imaging (MRI) has raised significant interest among researchers and clinicians …
resonance imaging (MRI) has raised significant interest among researchers and clinicians …
XD‐GRASP: golden‐angle radial MRI with reconstruction of extra motion‐state dimensions using compressed sensing
Purpose To develop a novel framework for free‐breathing MRI called XD‐GRASP, which
sorts dynamic data into extra motion‐state dimensions using the self‐navigation properties …
sorts dynamic data into extra motion‐state dimensions using the self‐navigation properties …
5D whole‐heart sparse MRI
Purpose A 5D whole‐heart sparse imaging framework is proposed for simultaneous
assessment of myocardial function and high‐resolution cardiac and respiratory motion …
assessment of myocardial function and high‐resolution cardiac and respiratory motion …
Recent advances in cardiovascular magnetic resonance: techniques and applications
Cardiovascular magnetic resonance imaging has become the gold standard for evaluating
myocardial function, volumes, and scarring. Additionally, cardiovascular magnetic …
myocardial function, volumes, and scarring. Additionally, cardiovascular magnetic …
Cardiac MR: from theory to practice
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality,
causing over 17. 9 million deaths worldwide per year with associated costs of over $800 …
causing over 17. 9 million deaths worldwide per year with associated costs of over $800 …
ECG and navigator‐free four‐dimensional whole‐heart coronary MRA for simultaneous visualization of cardiac anatomy and function
Purpose To develop a cardiac and respiratory self‐gated four‐dimensional (4D) coronary
MRA technique for simultaneous cardiac anatomy and function visualization. Methods A …
MRA technique for simultaneous cardiac anatomy and function visualization. Methods A …
Free‐running 4D whole‐heart self‐navigated golden angle MRI: initial results
Purpose To test the hypothesis that both coronary anatomy and ventricular function can be
assessed simultaneously using a single four‐dimensional (4D) acquisition. Methods A free …
assessed simultaneously using a single four‐dimensional (4D) acquisition. Methods A free …
Retrospective respiratory self‐gating and removal of bulk motion in pulmonary UTE MRI of neonates and adults
Purpose To implement pulmonary three‐dimensional (3D) radial ultrashort echo‐time (UTE)
MRI in non‐sedated, free‐breathing neonates and adults with retrospective motion tracking …
MRI in non‐sedated, free‐breathing neonates and adults with retrospective motion tracking …
A small surrogate for the golden angle in time-resolved radial MRI based on generalized fibonacci sequences
S Wundrak, J Paul, J Ulrici, E Hell… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
In golden angle radial magnetic resonance imaging a constant azimuthal radial profile
spacing of 111.246...° guarantees a nearly uniform azimuthal profile distribution in k-space …
spacing of 111.246...° guarantees a nearly uniform azimuthal profile distribution in k-space …