Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
On the capabilities of conventional x‐ray tubes to deliver ultra‐high (FLASH) dose rates
M Bazalova‐Carter, N Esplen - Medical physics, 2019 - Wiley Online Library
Purpose By means of Monte Carlo (MC) simulations and indirect measurements, we have
evaluated the maximum dose rates achievable with conventional x‐ray tubes and related …
evaluated the maximum dose rates achievable with conventional x‐ray tubes and related …
Heterogeneous multiscale Monte Carlo simulations for gold nanoparticle radiosensitization
Purpose To introduce the heterogeneous multiscale (Het MS) model for Monte Carlo
simulations of gold nanoparticle dose‐enhanced radiation therapy (GNPT), a model …
simulations of gold nanoparticle dose‐enhanced radiation therapy (GNPT), a model …
An investigation into the INTRABEAM miniature x‐ray source dosimetry using ionization chamber and radiochromic film measurements
PGF Watson, H Bekerat… - Medical …, 2018 - Wiley Online Library
Purpose Intraoperative radiotherapy using The INTRABEAM System (Carl Zeiss Meditec AG,
Jena, Germany), a miniature low‐energy x‐ray source, has proven to be an effective …
Jena, Germany), a miniature low‐energy x‐ray source, has proven to be an effective …
Determination of absorbed dose to water from a miniature kilovoltage x-ray source using a parallel-plate ionization chamber
PGF Watson, M Popovic… - Physics in Medicine & …, 2017 - iopscience.iop.org
Electronic brachytherapy sources are widely accepted as alternatives to radionuclide-based
systems. Yet, formal dosimetry standards for these devices to independently complement the …
systems. Yet, formal dosimetry standards for these devices to independently complement the …
Dose‐rate considerations for the INTRABEAM electronic brachytherapy system: report from the American association of physicists in medicine task group no. 292
WS Culberson, SD Davis, G Gwe‐Ya Kim… - Medical …, 2020 - Wiley Online Library
The purpose of this report is to provide detailed guidance on the dosimetry of the
INTRABEAM®(Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy (eBT) …
INTRABEAM®(Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy (eBT) …
A model for the emission of K and L x rays from an x-ray tube
An analytical model for the prediction of thick-target characteristic x-ray emission has been
developed and validated for several commonly used x-ray tube target materials. The model …
developed and validated for several commonly used x-ray tube target materials. The model …
Evaluation of dosimetry formalisms in intraoperative radiation therapy of glioblastoma
Purpose The intraoperative radiotherapy in newly diagnosed glioblastoma multiforme
(INTRAGO) clinical trial assesses survival in patients with glioblastoma treated with …
(INTRAGO) clinical trial assesses survival in patients with glioblastoma treated with …
Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams
V Giménez-Alventosa, V Giménez… - Physics in Medicine …, 2020 - iopscience.iop.org
The beam quality correction factor k Q for megavoltage photon beams has been calculated
for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010 …
for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010 …
Monte Carlo calculation of the relative TG-43 dosimetry parameters for the INTRABEAM electronic brachytherapy source
Abstract The INTRABEAM system (Carl Zeiss Meditec AG, Jena, Germany) is an electronic
brachytherapy (eBT) device designed for intraoperative radiotherapy applications. To date …
brachytherapy (eBT) device designed for intraoperative radiotherapy applications. To date …
Monte Carlo calculation of the TG-43 dosimetry parameters for the INTRABEAM source with spherical applicators
Objective: The relative TG-43 dosimetry parameters of the INTRABEAM (Carl Zeiss Meditec
AG, Jena, Germany) bare probe were recently reported by Ayala Alvarez et al (2020 Phys …
AG, Jena, Germany) bare probe were recently reported by Ayala Alvarez et al (2020 Phys …