A review of wood-frame low-rise building performance study under hurricane winds

J He, F Pan, CS Cai - Engineering structures, 2017 - Elsevier
The unsatisfying performance of light-frame low-rise buildings under hurricane winds is a
long-standing issue. Most past research effort has been made in creating a wind pressure …

The Florida coastal monitoring program (FCMP): A review

JA Balderrama, FJ Masters, KR Gurley… - Journal of Wind …, 2011 - Elsevier
The Florida Coastal Monitoring Program (FCMP) is a multi-university field research program
that was founded in 1998 to study the near-surface wind and rain characteristics of Atlantic …

The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 3. Internal pressures

JH Oh, GA Kopp, DR Inculet - Journal of wind engineering and industrial …, 2007 - Elsevier
Wind tunnel tests of generic low buildings have been conducted at the University of Western
Ontario for contribution to the National Institute on Standards and Technology (NIST) …

Wind-induced internal pressures in houses

GA Kopp, JH Oh, DR Inculet - Journal of Structural Engineering, 2008 - ascelibrary.org
The effects of ten different opening configurations on the internal pressures in a typical two-
story North American house were examined using volume-scaled, wind tunnel experiments …

Review of wind loading on roof to wall connections in low-rise light wood-frame residential buildings

KJ Alawode, KS Vutukuru, A Elawady… - Journal of Wind …, 2023 - Elsevier
Several post-hurricane studies have indicated the prevalence of roof damage in low-rise
wood-frame buildings. One of the major reasons for this includes failure of roof-to-wall …

Internal pressures–The dominant windward opening case–A review

JD Holmes, JD Ginger - Journal of wind engineering and industrial …, 2012 - Elsevier
A building with a dominant opening in a wall may experience internal pressures equal to, or
greater than, the external wind pressures in a severe windstorm. This is a critical design …

Tornado-like-vortex-induced wind pressure on a low-rise building with opening in roof corner

M Wang, S Cao, J Cao - Journal of Wind Engineering and Industrial …, 2020 - Elsevier
This study focuses on internal pressures and wind forces on a gable roof of a low-rise
building with an opening in the roof corner in stationary tornado-like vortices. Three roof …

[HTML][HTML] Effect of building volume and opening size on fluctuating internal pressures

JD Ginger, JD Holmes, GA Kopp - Wind and structures, 2008 - koreascience.kr
This paper considers internal pressure fluctuations for a range of building volumes and
dominant wall opening areas. The study recognizes that the air flow in and out of the …

Net pressures on the roof of a low-rise building with wall openings

RN Sharma, PJ Richards - Journal of wind engineering and industrial …, 2005 - Elsevier
This paper deals with an investigation of the characteristics of net pressures on two
significant roof areas of a low-rise building with two different dominant wall openings. Wind …

Wind-induced internal pressures in buildings with large façade openings

P Karava, T Stathopoulos - Journal of engineering mechanics, 2012 - ascelibrary.org
The paper presents the results of a study that investigated the effects of wall porosity, inlet-to-
outlet-ratio, opening location, and blockage on internal pressure in buildings with large …