Development and initial results of a brain PET insert for simultaneous 7-Tesla PET/MRI using an FPGA-only signal digitization method
In study, we developed a positron emission tomography (PET) insert for simultaneous brain
imaging within 7-Tesla (7T) magnetic resonance (MR) imaging scanners. The PET insert …
imaging within 7-Tesla (7T) magnetic resonance (MR) imaging scanners. The PET insert …
[HTML][HTML] A comprehensive survey of readout strategies for SiPMs used in nuclear imaging systems
Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size,
and lower operating voltages compared to photomultiplier tubes. A SiPM's readout circuit …
and lower operating voltages compared to photomultiplier tubes. A SiPM's readout circuit …
Development of multichannel high time resolution data acquisition system for TOT-ASIC
S Sato, M Uenomachi… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
We developed a multichannel high time resolution data acquisition (DAQ) system for time-
over-threshold (TOT) application specific integrated circuit (ASIC). The developed field …
over-threshold (TOT) application specific integrated circuit (ASIC). The developed field …
A preclinical PET detector constructed with a monolithic scintillator ring
This paper presents a unique preclinical positron emission tomography (PET) detector
constructed with a monolithic scintillator ring (MSR) and two rings of silicon photomultipliers …
constructed with a monolithic scintillator ring (MSR) and two rings of silicon photomultipliers …
Design study of a PET detector with 0.5 mm crystal pitch for high-resolution preclinical imaging
Preclinical positron emission tomography (PET) is a sensitive and quantitative molecule
imaging modality widely used in characterizing the biological processes and diseases in …
imaging modality widely used in characterizing the biological processes and diseases in …
A depth encoding PET detector using four‐crystals‐to‐one‐SiPM coupling and light‐sharing window method
Purpose Depth of interaction (DOI) decoding capability is of great importance for positron
emission tomography (PET) requiring high resolution. In this study, we presented a novel …
emission tomography (PET) requiring high resolution. In this study, we presented a novel …
Comparator-less PET data acquisition system using single-ended memory interface input receivers of FPGA
In this study, we propose a linear field-programmable gate array (FPGA)-based charge
measurement method by combining a charge-to-time converter (QTC) with a single-ended …
measurement method by combining a charge-to-time converter (QTC) with a single-ended …
A compact and highly integrated 128-channel FPGA-based readout electronics for nuclear imaging application
B Wang, X Sun, Y Li, C Li, Y Du, K Hu - Nuclear Instruments and Methods …, 2024 - Elsevier
As silicon photomultiplier (SiPM) technology develops, its possible applications are being
growingly expanded. However, the current technical obstacle is the signal readout from …
growingly expanded. However, the current technical obstacle is the signal readout from …
A custom 70-channel mixed signal ASIC for the brain-PET detectors signal readout and selection
SM Qaisar - Biomedical Physics & Engineering Express, 2019 - iopscience.iop.org
This paper presents a 70-channel mixed signal Application Specific Integrated Circuit (ASIC)
for Silicon Photo-Multipliers (SiPM) detectors, used in the axial architecture based Time of …
for Silicon Photo-Multipliers (SiPM) detectors, used in the axial architecture based Time of …
Study on properties of a hybrid photomultiplier tube based on a SiC Schottky diode combined with an MCP
J Ruan, L Chen, P Xu, Y Zhang, X Du… - IEEE Transactions …, 2024 - ieeexplore.ieee.org
Scintillation detector is one of the key detectors for measurements of pulsed radiation fields
due to its high sensitivity and fast time response. In a scintillation detector, the …
due to its high sensitivity and fast time response. In a scintillation detector, the …