Thermal neutron beam optimization for PGNAA applications using Q-learning algorithm and neural network
As a powerful, non-destructive analysis tool based on thermal neutron capture reaction,
prompt gamma neutron activation analysis (PGNAA) indeed requires the appropriate …
prompt gamma neutron activation analysis (PGNAA) indeed requires the appropriate …
Monte Carlo design and experimental characterization of a moderator device to produce a thermal neutron source from a 241Am/9Be source
A moderator device to produce a uniform thermal neutron field has been designed by Monte
Carlo methods using the MCNP6. 1 code. It uses a 241 Am/9 Be neutron source of 111 GBq …
Carlo methods using the MCNP6. 1 code. It uses a 241 Am/9 Be neutron source of 111 GBq …
Comparison of extended-range and conventional Bonner Sphere Spectrometers (BSS) in an AmBe neutron field–Applicability of the ReBUNKI unfolding code for …
R García-Baonza, A Lorente, S Ibáñez… - Radiation Physics and …, 2023 - Elsevier
In proton therapy facilities, high-energy neutron fields are generated as a consequence of
(p, Xn) nuclear interactions. UPM has designed and tested its own extended-range Bonner …
(p, Xn) nuclear interactions. UPM has designed and tested its own extended-range Bonner …
Application of an algebraic methodology for the combination of Berthold LB6411 and WENDI-II for neutron area monitoring in DT neutron generators and fusion …
R García-Baonza, E Gallego… - Applied Radiation and …, 2022 - Elsevier
Neutron area monitors do not often have a good adjustment of their dose response functions
to the ICRP74 neutron fluence-to-H*(10) conversion function between 10 and 20 MeV. The …
to the ICRP74 neutron fluence-to-H*(10) conversion function between 10 and 20 MeV. The …
Estimation with Monte Carlo of thermal neutrons in the FANT, using 252Cf and 241Am/9Be neutron source
The thermal neutron irradiation device (FANT), developed at the Neutron Measurements
Laboratory of the Energy Engineering Department at Universidad Politécnica de Madrid, is a …
Laboratory of the Energy Engineering Department at Universidad Politécnica de Madrid, is a …
Conceptual design of a new multi-purpose, passive and flexible neutron area monitor with two configurations
R García-Baonza, A Lorente, S Ibáñez… - Radiation Physics and …, 2022 - Elsevier
In proton therapy facilities, high-energy neutron fields are generated as a consequence of
(p, Xn) nuclear interactions. UPM has designed and manufactured, for these facilities, a new …
(p, Xn) nuclear interactions. UPM has designed and manufactured, for these facilities, a new …
[PDF][PDF] Comparison of experimental and MCNP6 results for a LUPIN-II neutron REM-meter at the UPM neutronics hall
LUPIN-II is a recently developed wide-range neutron REM-meter. Designed for the control of
the ambient dose equivalent H*(10) due to neutron fields generated in high-energy pulsed …
the ambient dose equivalent H*(10) due to neutron fields generated in high-energy pulsed …
Feasibility of using 10 MeV electron LINAC for explosives detection based on thermal neutron activation analysis: a Monte Carlo study
M Mohammad Rafiei, H Tavakoli-Anbaran - The European Physical …, 2020 - Springer
In the present paper, we used the MCNPX code for the feasibility of the design of a
conceptional explosives detection system based on a neutron source generated by a 10 …
conceptional explosives detection system based on a neutron source generated by a 10 …
[PDF][PDF] Actualización del modelo MCNP del contenedor Howitzer de la Universidad Politécnica de Madrid
R García-Baonza, E Gallego… - Actas de la Reunión …, 2020 - sendaeventos.com
La actualización y mejora continua en la dosimetría de neutrones y benchmarking es una
de las actividades desarrolladas en el Laboratorio de Medidas Neutrónicas de la …
de las actividades desarrolladas en el Laboratorio de Medidas Neutrónicas de la …
Análisis y diseño de sistemas de dosimetría y espectrometría neutrónica ambiental para instalaciones médicas de hadronterapia
R García Baonza - 2023 - oa.upm.es
El desarrollo de tratamientos de hadronterapia más precisos y potentes, como la
protonterapia o la terapia con iones de 12C, requiere del empleo de aceleradores de …
protonterapia o la terapia con iones de 12C, requiere del empleo de aceleradores de …