Energy dissipation systems for seismic applications: current practice and recent developments

MD Symans, FA Charney, AS Whittaker… - Journal of structural …, 2008 - ascelibrary.org
This paper presents a summary of current practice and recent developments in the
application of passive energy dissipation systems for seismic protection of structures. The …

Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper

K Ikago, K Saito, N Inoue - Earthquake Engineering & Structural …, 2012 - Wiley Online Library
In this study, we propose a new seismic control device, tuned viscous mass damper (TVMD),
for building systems. We give a detailed description of an apparent mass amplifier using a …

Demand‐based optimal design of oscillator with parallel‐layout viscous inerter damper

C Pan, R Zhang, H Luo, C Li… - Structural Control and …, 2018 - Wiley Online Library
In this study, a demand‐based optimal design method is proposed for an oscillator (a single‐
degree‐of‐freedom system) with a parallel‐layout viscous inerter damper (PVID). The …

Design and evaluation of tuned inerter-based dampers for the seismic control of MDOF structures

Y Wen, Z Chen, X Hua - Journal of Structural Engineering, 2017 - ascelibrary.org
The tuned viscous mass damper (TVMD) and tuned inerter damper (TID) are tuned inerter-
based dampers (TIBDs) that can utilize amplified apparent mass and tuning effects. This …

An optimum retrofit strategy for moment resisting frames with nonlinear viscous dampers for seismic applications

M Martinez-Rodrigo, ML Romero - Engineering structures, 2003 - Elsevier
The dynamic response of a multi-story steel moment resisting frame (MRF) equipped with
fluid viscous (VS) dampers and subjected to seismic loads is investigated numerically. The …

Optimal damper distribution for seismic rehabilitation of planar building structures

E Aydin, MH Boduroglu, D Guney - Engineering Structures, 2007 - Elsevier
In this study, the variations of optimal damper placement using different objective functions
are presented. Instead of the usual choice of transfer function amplitude of the top …

Application of a genetic algorithm for optimal damper distribution within the nonlinear seismic benchmark building

N Wongprasert, MD Symans - Journal of Engineering Mechanics, 2004 - ascelibrary.org
This paper presents a systematic method for identifying the optimal damper distribution to
control the seismic response of a 20-story benchmark building. A genetic algorithm with …

Multiple tuned inerter-based dampers for seismic response mitigation of continuous girder bridges

R Liang, H Wang, J Li, H Gao, W Zheng, Z Xu - Soil Dynamics and …, 2021 - Elsevier
Tuned inerter-based dampers (TIBDs), such as the tuned viscous mass damper (TVMD) and
tuned inerter damper (TID), have demonstrated better control performance compared with …

Analysis of efficiency of passive dampers in multistorey buildings

E Aydin, B Öztürk, M Dutkiewicz - Journal of Sound and Vibration, 2019 - Elsevier
In this study, optimum design of viscous dampers under different mode behaviors are
investigated for structures exposed to earthquakes. The structure is modeled as a shear …

[KİTAP][B] Smart civil structures

YL Xu, J He - 2017 - taylorfrancis.com
A smart civil structure integrates smart materials, sensors, actuators, signal processors,
communication networks, power sources, diagonal strategies, control strategies, repair …