Characterization of large-area SiPM array for PET applications
The performance of an 8*8 array of 6.0*6.0~mm^2 (active area) SiPMs was evaluated for
PET applications using crystal arrays with different pitch sizes (3.4, 1.5, 1.35, and 1.2 mm) …
PET applications using crystal arrays with different pitch sizes (3.4, 1.5, 1.35, and 1.2 mm) …
Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays
The goal of this study was to exploit the excellent spatial resolution characteristics of a
position-sensitive silicon photomultiplier (SiPM) and develop a high-resolution depth-of …
position-sensitive silicon photomultiplier (SiPM) and develop a high-resolution depth-of …
A time-walk correction method for PET detectors based on leading edge discriminators
The leading edge timing pick-off technique is the simplest timing extraction method for PET
detectors. Due to the inherent time-walk of the leading edge technique, corrections should …
detectors. Due to the inherent time-walk of the leading edge technique, corrections should …
A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays
The performance of a depth-of-interaction (DOI) encoding PET detector module with dual-
ended readout of LYSO scintillator arrays using large-area SiPM arrays was evaluated …
ended readout of LYSO scintillator arrays using large-area SiPM arrays was evaluated …
Gaussian position-weighted center of gravity algorithm for multiplexed readout
H Poladyan, O Bubon, A Teymurazyan… - Physics in Medicine …, 2020 - iopscience.iop.org
Readout signal multiplexing is a commonly used method to reduce the electronics cost in
positron emission tomography (PET) systems, and the calculation of the scintillation …
positron emission tomography (PET) systems, and the calculation of the scintillation …
Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes
DY Domínguez‐Jiménez, H Alva‐Sánchez - Medical Physics, 2021 - Wiley Online Library
Purpose Most detectors in current positron emission tomography (PET) scanners and
prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) …
prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) …
Evaluation of two SiPM arrays for depth-encoding PET detectors based on dual-ended readout
Q Yang, X Wang, Z Kuang, C Zhang… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
In this article, two latest silicon photomultiplier (SiPM) arrays from Hamamatsu and
Broadcom were evaluated for high-resolution dual-ended readout positron emission …
Broadcom were evaluated for high-resolution dual-ended readout positron emission …
Development of a multiplexed readout with high position resolution for positron emission tomography
Detector signals for positron emission tomography (PET) are commonly multiplexed to
reduce the number of digital processing channels so that the system can remain cost …
reduce the number of digital processing channels so that the system can remain cost …
Generic high resolution PET detector block using 12× 12 SiPM array
With the advancement of the Silicon Photomultiplier (SiPM) technology, these devices are
becoming the mainstream for use in high resolution PET detectors especially where the …
becoming the mainstream for use in high resolution PET detectors especially where the …
Design and optimization of a high-resolution PET detector module for small-animal PET based on a 12× 12 silicon photomultiplier array
A high resolution PET detector module was designed and optimized based on a custom 12×
12 Silicon photomultiplier (SiPM) array and commercially available readout electronics …
12 Silicon photomultiplier (SiPM) array and commercially available readout electronics …