[HTML][HTML] Fluoride contamination in groundwater: A global review of the status, processes, challenges, and remedial measures

E Shaji, KV Sarath, M Santosh, PK Krishnaprasad… - Geoscience …, 2024 - Elsevier
Groundwater pollution by fluoride is one of the prime concerns of the world population due
to its toxicity, which results in adverse health impacts. In this paper, we review the current …

Molecular absorption spectrometry in flames and furnaces: A review

DJ Butcher - Analytica Chimica Acta, 2013 - Elsevier
Molecular absorption spectrometry (MAS), originally developed in the 1970s, is a technique
to determine non-metals in flames and graphite furnaces by monitoring the absorbance of …

Continuum source atomic absorption spectrometry: past, present and future aspects-a critical review

B Welz, MGR Vale, ÉR Pereira, INB Castilho… - Journal of the Brazilian …, 2014 - SciELO Brasil
This review article covers 1½ centuries of history of continuum source atomic absorption
spectrometry (CS AAS), starting with the early experiments of Kirchhoff and Bunsen in the …

Fluoride in the context of the environment

MG García, L Borgnino - 2015 - books.rsc.org
Fluoride has interesting properties related to human health, particularly in preventing dental
caries. However, when it is concentrated in drinking water at levels higher than 1 mg l− 1, a …

Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical …

M Resano, MR Flórez, E García-Ruiz - Analytical and bioanalytical …, 2014 - Springer
This work examines the new possibilities introduced with the arrival of commercially
available high-resolution continuum source atomic absorption spectrometers for the …

The use of high resolution graphite furnace molecular absorption spectrometry (HR-MAS) for total fluorine determination in extractable organofluorines (EOF)

A Akhdhar, M Schneider, A Orme, L Schultes, A Raab… - Talanta, 2020 - Elsevier
The determination of total fluorine content using high-resolution graphite furnace continuum
source molecular absorption spectrometry (HR-MAS) has been employed in a variety of …

Recent developments for spectrometric, chromatographic and electroanalytical determination of the total sulphur and halogens in various matrices

E Tjabadi, N Mketo - TrAC Trends in Analytical Chemistry, 2019 - Elsevier
Sulphur and halogens (fluorine, chlorine, bromine and iodine) are nonmetallic elements that
are found in various matrices, where their existence can be in the form of an impurity or of …

Screening method for extractable organically bound fluorine (EOF) in river water samples by means of high-resolution–continuum source graphite furnace molecular …

M Metzger, P Ley, M Sturm, B Meermann - Analytical and Bioanalytical …, 2019 - Springer
The introduction of fluorine into organic molecules leads to new chemical/physical
properties. Especially in the field of pharmaceutical as well as technical applications …

Novel non-target analysis of fluorine compounds using ICPMS/MS and HPLC-ICPMS/MS

NLA Jamari, JF Dohmann, A Raab, EM Krupp… - Journal of Analytical …, 2017 - pubs.rsc.org
Measuring sub-ppm levels of fluorine (F) directly with a commercial ICPMS is not possible
due to the high ionisation potential of F. Mixing of barium and fluorine solutions enabled a …

Determination of fluorine in milk and water via molecular absorption of barium monofluoride by high-resolution continuum source atomic absorption spectrometer

N Ozbek, S Akman - Microchemical Journal, 2014 - Elsevier
This study describes the determination of fluorine evaluating the molecular absorption of
barium monofluoride (BaF) at the rotational lines of 495.088 and 495.263 nm simultaneously …